Two Sets 120KVA UPS Dual Utility Feed A-Tier without Maintenance Bypass Delixi Total Capacity 400A Standard Distribution with 3 units 60kW Air Conditioner
Dual Utility Feed Total Capacity 400A Output 75 Rack 120KVA UPS 2 units Data Room Air Conditioner 30KW 3 sets

Four Sets, 3-Phase In / 3-Phase Out 20KVA UPS Single Utility Feed B-Tier without Maintenance Bypass Delixi Total Capacity 160A Standard Distribution with 2 units 25kW Air Conditioner
Four Sets, 3-Phase In / 3-Phase Out 20KVA UPS Single Utility Feed B-Tier without Maintenance Bypass Delixi Total Capacity 160A Standard Distribution with 2 units 25kW Air Conditioner

Two Sets 120KVA UPS Dual Utility Feed A-Tier without Maintenance Bypass CHINT Total Capacity 400A Standard Distribution with 3 units 60kW Air Conditioner
Dual Utility Feed Total Capacity 400A Output 75 Rack Utility CHINT 120KVA UPS2 units

Two Sets 120KVA UPS Dual Utility Feed A-Tier without Maintenance Bypass Schneider Total Capacity 400A Standard Distribution with 3 units 60kW Air Conditioner
Dual Utility Feed Total Capacity 400A Output 75 Rack Schneider 120KVA UPS2 units

Two Sets 120KVA UPS Dual Utility Feed A-Tier without Maintenance Bypass ABB Total Capacity 400A Standard Distribution with 3 units 60kW Air Conditioner
Dual Utility Feed Total Capacity 400A Output 75 Rack ABB 120KVA UPS2 units

30KVA UPS Single Utility Feed C-Tier with Maintenance Bypass CHINT Total Capacity 125A Standard Distribution with 5.5kW Air Conditioner
30KVA UPS Single Utility Feed C-Tier with Maintenance Bypass CHINT Total Capacity 125A Standard Distribution with 5.5kW Air Conditioner

6KVA UPS Single Utility Feed C-Tier with Maintenance Bypass Delixi Total Capacity 63A Standard Distribution with 7.5kW Air Conditioner
6KVA UPS Manual Maintenance Bypass-Circuit Dual Circuit Power Solution

3-Phase In / 3-Phase Out 10KVA UPS Single Utility Feed C-Tier with Maintenance Bypass CHINT Total Capacity 100A Standard Distribution with 12.5kW Air Conditioner
3-Phase In / 3-Phase Out 10KVA UPS Single Utility Feed C-Tier with Maintenance Bypass CHINT Total Capacity 100A Standard Distribution with 12.5kW Air Conditioner

3-Phase In / 3-Phase Out 10KVA UPS Single Utility Feed C-Tier with Maintenance Bypass Schneider Total Capacity 80A Standard Distribution with 2 units 7.5kW Air Conditioner
10KUPS Power 7.5KW Air Conditioner 11-Circuit

Two Sets 60KVA UPS Dual Utility Feed C-Tier with Maintenance Bypass CHINT Total Capacity 200A Precision Distribution
Total Capacity 200A Dual Utility Power Input CHINT Configuration 60KVAUPS Precision Distribution Output

Two Sets 60KVA UPS Dual Utility Feed C-Tier with Maintenance Bypass ABB Total Capacity 200A Precision Distribution
Total Capacity 200A Dual Utility Power Input ABB Configuration 60KVAUPS Precision Distribution Output

Two Sets 60KVA UPS Dual Utility Feed C-Tier with Maintenance Bypass Schneider Total Capacity 200A Precision Distribution
Total Capacity 200A Dual Utility Power Input Schneider Configuration 60KVAUPS Precision Distribution Output